ADLINK Technology cPCI-9116 Betriebsanweisung Seite 53

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 67
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 52
Operation Theory 43
(M_Counter=M=3, DIV_Counter=4, SC_Counter=N=1)
Acquisition_in_progress
Scan_start
AD_conversion
Scan_in_progress
(
SSH_OUT
)(pin47)
Aquired data
Acquired & stored data
(M+N scans)
Operation start
ExtTrg(pin46)
M scans before
trigger
N scans
after trigger
Trigger signals which occur in the shadow
region(the first M scans) will be ignored
The first M scans
Figure 14: Middle trigger with M_enable = 1
If an external trigger event occurs when a scan is in progress, the stored N
scans of data would include this scan. And the first stored data will always
be the first channel entry of a scan, as illustrated in Fig 15.
Seitenansicht 52
1 2 ... 48 49 50 51 52 53 54 55 56 57 58 ... 66 67

Kommentare zu diesen Handbüchern

Keine Kommentare