ADLINK Technology cPCI-9116 Betriebsanweisung Seite 54

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 67
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 53
44 Operation Theory
(M_Counter=M=2, DIV_Counter=4, SC_Counter=N=2)
Acquisition_in_progress
Scan_start
AD_conversion
Scan_in_progress
(SSH_OUT)(pin47)
Acquired data
Acquired & stored data
(M+N scans)
Trigger occurs when a scan is in progress
Operation start
ExtTrg(pin46)
M scans before
trigger
N scans
after trigger
Figure 15: Middle trigger (trigger with scan is in progress)
Post-Trigger Acquisition
Use post-trigger acquisition in applications where you want to collect data after
an external trigger event. The number of scans after the trigger is specified in
SC_counter, as illustrated in fig 16. The total acquired data length =
DIV_counter *SC_counter.
(DIV_Counter=4, SC_Counter=3)
Acquisition_in_progress
Scan_start
AD_conversion
Scan_in_progress
(SSH_OUT)
Acquired & stored data
(3 scans)
Operation start
ExtTrg
Figure 16: Post trigger
Seitenansicht 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 66 67

Kommentare zu diesen Handbüchern

Keine Kommentare